MD100N Industrial Spectroradiometer |
||
Spectrum |
||
Sensor | CMOS Linear Image Sensor | |
Wavelength Range | 380 to 780 nm | |
Wavelength Data Increment | 1 nm | |
Spectral Bandwidth | Approximately 12 nm (Half Bandwidth) | |
Receptor Size | Ø 10 mm | |
Acceptance angle | ±1° | |
Wavelength Reproducibility | ± 1 nm*1 | |
Display Range | 0.001 to 5000 cd/m2 | |
Luminance *2 | Measurement range | 0.05~5000 cd/m2 |
Accuracy | ±2% 100 to 5000 cd/m2 | |
±3% 0.2 to 100 cd/m2 | ||
±4% 0.05 to 0.2 cd/m2 | ||
Repeatability (2σ) | 0.2% 100 to 5000 cd/m2 | |
0.5% 0.2 to 100 cd/m2 | ||
0.8% 0.05 to 0.2 cd/m2 | ||
Color*2 | Measurement range | 0.05~5000 cd/m2 |
Accuracy | ±0.002 in CIE1931 x, y for white 100 to 5000 cd/m2 | |
±0.003 in CIE1931 x, y for white 0.2 to 100 cd/m2 | ||
±0.005 in CIE1931 x, y for white 0.05 to 0.2 cd/m2 | ||
Repeatability (2σ) | 0.0005 in CIE1931 x, y for white 100 to 5000 cd/m2 | |
0.001 in CIE1931 x, y for white 0.2 to 100 cd/m2 | ||
0.002 in CIE1931 x, y for white 0.05 to 0.2 cd/m2 | ||
Stray Light | -25 dB max.*3 | |
Polarized Error | <2% | |
Integration Time Range | 100us to 5000 ms (fast mode/normal mode) | |
Digital Resolution | 16 bits | |
Flicker |
||
Measurement Range | 5cd/m2 or higher | |
Sampling Rate | 100k sample/sec (adjustable) | |
Contrast | Accuracy | ±1%(30Hz AC/DC 10% sine wave) |
±2%(60Hz AC/DC 10% sine wave) | ||
Reproducibility | 1%(20 to 65 Hz AC/DC 10% sine wave) | |
JEITA | Accuracy | ±0.5dB(30Hz AC/DC 10% sine wave) |
Reproducibility | 0.3dB(30 Hz AC/DC 10% sine wave) | |
Feature | ||
Capture Function | One time/Continuous | |
Operation Mode | Standalone Mode/USB Mode | |
Integration Mode | Auto/Manual | |
Dark Calibration | Yes (Auto) | |
Measuring Modes |
1. Basic Mode | |
2. Spectrum Mode | ||
3. CIE 1931 Chromaticity Mode | ||
4. CIE 1976 Chromaticity Mode | ||
5. Browser Mode | ||
6. Flicker Mode | ||
7. Frequency Mode | ||
8. Browser Mode | ||
9. Option Mode | ||
Measuring Capabilities |
1 Luminance (cd/m2) | |
2. Correlated Color Temperature (CCT) | ||
3. CIE Chromaticity Coordinates | ||
(1) CIE 1931 2-degree, 10-degree x,y Coordinates | ||
(2) CIE 1976 2-degree, 10-degree u’,v’ Coordinates | ||
(3) CIE 1931 XYZ Value | ||
4. △x, △y, △u’, △v’ | ||
5. Dominant Wavelength (λd) | ||
6. Excitation Purity | ||
7. Color Rendering Index (CRI, Ra)/R1 to R15 | ||
8. Spectral Power Distribution (SPD) mW/m2 | ||
9. Peak Wavelength (λp) | ||
10. Peak Wavelength Value (λpV) | ||
11. Integration Time (I-Time) | ||
12. Scotopic and Photopic Ratio (S/P) | ||
Measuring Capabilities(Flicker) |
1. Max/Min, Average, RMS and Frequency | |
2. JEITA | ||
3. VESA | ||
4. Flicker Percentage (IES) | ||
5. Flicker Index (IES) | ||
System Configurations |
||
Power | Adapter; USB; 2500 mAh | |
Dimensions | 204 x 90 x 45mm (H x W x D) | |
Weight (with Battery) | 650 g ± 10 g | |
Operating Temperature/Humidity | 0 to 35 ℃, relative humidity 70% or less without condensation | |
Storage Temperature/Humidity | -10 to 40 ℃, relative humidity 70% or less without condensation |
MD100N Industrial Spectroradiometer
LCD / OLED / microLED Display Test and measurement, Spectroradiometer and Color Measurement
Display Panel manufacturers know that it’s troublesome to maintain image quality consistency in their panels, from product to product, batch to batch.
Additionally, there has been an influx of new display technologies (LED, OLED, BLU, MiniLED, MicroLED) and applications (Microdisplay, AR/VR). And with them, come new challenges in light performance, quality, and safety (Lv, color accuracy, contrast, gamma, metamerism, visual eye safety, etc).
These manufacturers certainly have laboratory-level light measurement instrumentation to address these inconsistencies, but they are often cost-prohibitive, bulky, and painfully time-consuming to use on production lines.
The MD100N is a spectroradiometer that is cost-effective, with fast measurement times, and a focus on Laboratory-level precision. It can be used by manufacturers, and OEM/ODM companies of any size and allows much more flexibility and versatility for inline product inspection.
MD100N Desktop Spectroradiometer
- Diffraction grating technology.
- Full Flicker metrics (JEITA, CONTRAST, VESA, RMS, FFT).
- SDK interface allows own RD efforts to integrate with MD100N data.
- MD100N must be used with an accompanying PC/Laptop. USB or RS232 cable connection.
- Different receptor sizes for smaller displays (e.g. watches).
- Supported by several 3rd party tuning tools.
DELIVERY
within 48 hrs after confirmed payment.
INCLUDING
3 years full product warranty.
INCLUDING
1 free UPRTEK Lighting Handbook.
INCLUDING
One free calibration during guarantee periode
INCLUDING
free firmware updates.
INCLUDING
free technical support.
INCLUDING
7 days money back guaranty (in consultion).
EXCLUDING
Transport & Insurance costs €34,75.
PRICES
All Prices are Excluding VAT.
PAYMENT
by PayPal, VISA, MasterCard, American Express or Bank Transfer.
Additional information
MEASURING CAPABILITIES | |
---|---|
INDUSTRIES | BROADCASTING, DISPLAY MANUFACTURING & CALIBRATION, FILM & ENTERTAINMENT |
SOFTWARE & APPLICATIONS |
Additional
Spectrometer as a Service | No |
---|
Firmware download
Contact us for the latest free firmware updates.
Best regards,
UPRtek europe
You must be logged in to post a review.
There are no reviews yet.